and plastic. For mounting the instrument is equipped with a
threaded pin Pg 21 and 2 nuts.
Order-No. 4.3519.00.000
- Measuring range 0,5 ... 50 m/s
- Accuracy ± 3 % of meas. value or ± 0,5 m/s
- Resolution < 0,1 m/s
- Electr. output 2 … 630Hz
- Operating voltage 3,3 - 42 V DC
- Current consumption < 1 mA
- Heating max. 20 W; 24 V AC/DC
- Ambient temperature -30 - +70 °C
- Cable 12m , LiYCY 6x0,25 mm²
- Dimension Ø 135 x 165 mm
- Weight 0,75 kg
Order-No.4.3519.00.xxx
- Electr. output Load (with operating voltage)
- 0-20 mA max. 500 Ω; (>13 V DC)
- 4-20 mA max. 500 Ω; (>13 V DC)
- 0-10 V min. 1 kΩ
- 0-2 V min. 1 kΩ
- 0-5V min. 1 kΩ
- Measuring range 0,5 ... 50 m/s
- Accuracy ± 3 % of meas. value or ± 0,5 m/s
- Resolution < 0,1 m/s
- Operating voltage 9-30 V DC or 24 V AC/DC
- for 0-10 V output 13-30 V DC
- Current consumption approx. 10 mA, unloaded
- Heating max. 20 W; 24 V AC/DC
- Ambient temperature -30 - +70 °C
- Cable 12m , LiYCY 6x0,25 mm²
- Dimension Ø 135 x 165 mm
- Weight 0,75 kg
CV Globalindo Teknik Mandiri
(Divisi Alat Test & Klimatologi)
Jl. Raya Johar No.26 RT 5/4 Kel.Cibadak,
Kec.Tanah Sareal, Kota Bogor 16161
Telp/Fax:
0858 8888 7980
0813 1421 0880
Email:
info@globalindoteknikmandiri.co.id